Pilkington Pyrostop

Pilkington Pyrostop® Fire-Resistive Glass

Transparent wall panels that stop flames, smoke AND radiant heat – fire-rated up to 2 hours.

Pilkington Pyrostop® is a fire-resistive, impact safety-rated glass that does more than contain flames – it blocks radiant and conductive heat, protecting people and property on the non-fire side. That makes it the right choice where heat transfer is a concern or where the glazing needs to perform as part of a fire-rated wall.
Built from multiple layers of nearly colourless Pilkington Optiwhite™ low-iron float glass and clear intumescent interlayers, Pyrostop is listed for doors, sidelites, transoms, borrowed lites and full glass wall applications, indoors and out.

KEY FEATURES & BENEFITS

  • Heat barrier – Protects against radiant and conductive heat transfer; tested to ASTM E119 / UL 263.
  • Up to 2 hours – Fire-rated up to 120 minutes, including the required hose stream test.
  • Impact safety-rated – Meets ANSI Z97.1 and CPSC 16 CFR 1201 (Category I and II).
  • True multi-laminate – Layers of Optiwhite™ glass and clear intumescent interlayers – not a sensitive polymer gel unit.
  • Interior or exterior – Suitable for both, including insulated units with tinted, art glass, one-way mirror, Low-E, reflective or security glass.
  • Privacy option – Most configurations can be supplied with a translucent interlayer.
  • Security upgrade – Available with bullet resistance to UL Level III.
  • Integrated louvres – Can be combined with Vision Control® cord-free louvres in a UL-tested fire protection-rated system (available from Unicel Architectural).
  • Durable and flexible – Withstands thermal shock; large sizes available; may be lightly sandblasted or etched on one side without affecting the rating.
  • Framing – Fits most Fireframes® frame and door systems. 5-year limited warranty.
  • Performance at a Glance

    Fire-rated

    Hose stream tested

    Positive pressure tested

    Heat Barrier

    Impact safety-rated

    Bullet resistant (option)

    UL classified and labeled

    Ratings & Specifications

    Listings & Maximum Sizes

    Listed with Underwriters Laboratories Inc.® – UL File No. R13377 (45 minutes) and R38725 (60 to 120 minutes).

    Interior Applications

    Fire rating

    Manufacturer's designation

    Supply form

    Nominal thickness
     

    Approx. weight (lb/ft²)

    U-value

    Approx. daylight transmission (%)

    Approx. STC

    Max. exposed area – other than doors (in²)

    Max. exposed area – doors (in²)
     

    45 min.

    45-200

    Single glazing

    3/4" (19 mm)
     

    9.22

    .86

    86

    40

    4,500 (95-1/4" W × 95-1/4" H max.)

    3,724 (41-5/8" W × 89-3/4" H max.)

    60 min.

    60-101

    Single glazing

    7/8" (23 mm)
     

    10.86

    .83

    87

    41

    5,616 (96" × 96" max.)
     

    4,222 (41-7/8" W × 100-13/16" H max.)

    60min.

    60-201

    Single glazing

    1-1/16" (27 mm)
     

    12.90

    .83

    86

    44

    7,442 (96" W × 118-1/8" H max.)
     

    4,222 (41-7/8" W × 100-13/16" H max.)

    90min.

    90-102

    Single glazing

    1-7/16" (37 mm)
     

    17.61

    .74

    84

    45

    3,724 (96" × 96" max.)
     

    4,222 (41-7/8" W × 100-13/16" H max.)

    2 hr.

    120-104

    I.G. unit

    2-1/8" (54 mm) w/ 8 mm spacer, or 2-3/8" (60 mm) w/ 14 mm spacer

    21.71

    .44

    74

    46

    3,730 (111" × 111" max.)
     

    N/A
     

    Exterior Applications

    Fire rating

    Manufacturer's designation

    Supply form

    Nominal thickness
     

    Approx. weight (lb/ft²)

    U-value

    Approx. daylight transmission (%)

    Approx. STC

    Max. exposed area – other than doors (in²)

    Max. exposed area – doors (in²)

    45 min.

    45-200; 45-260 (IGU); 45-360* (IGU)

    Single glazing or I.G. unit

    3/4" (19 mm); IGU 1-5/16" (33 mm)
     

    9.22; 12.29 (IGU)

    45-200: .86 / 45-260: .49 / 45-360: .37–.39

    86; 77 (IGU)

    40

    4,500 (95-1/4" W × 95-1/4" H max.)

    3,724 (41-5/8" W × 89-3/4" H max.)

    60 min.

    60-201; 60-261 (IGU); 60-361* (IGU)

    Single glazing or I.G. unit

    1-1/16" (27 mm); IGU 1-5/8" (41 mm)
     

    12.90; 15.98 (IGU)

    60-201: .83 / 60-261: .48 / 60-361: .37–.39

    86; 77 (IGU)

    44

    7,442 (96" W × 118-1/8" H max.)

    4,222 (41-7/8" W × 100-13/16" H max.)

    90 min. – 2 hr.

    120-202; 120-262 (IGU); 120-362* (IGU)

    Single glazing or I.G. unit

    1-9/16" (40 mm); IGU 2-3/8" (60 mm) w/ 14 mm spacer or 2-1/8" (54 mm) w/ 8 mm spacer

    18.64; 21.71 (IGU)

    120-202: .72 / 120-262: .44 / 120-362: .35

    86; 77 (IGU)

    46

    3,730 (111" × 111" max.)

    4,222 (41-7/8" W × 100-13/16" H max.)

    * Exterior I.G. unit performance depends on the face-2 coating (Eclipse Advantage Clear, Solar E Solar Control Low-E or Energy Advantage Low-E). Sizes may vary by framing system. For general reference only – confirm current listing details before specifying.

    Tested To

    UL 9 · UL 10B · UL 10C · UL 263 · NFPA 80 · NFPA 252 · NFPA 257 · CAN/ULC-S101 · CAN/ULC-S104 · CAN/ULC-S106 · ASTM E119 · MEA 241-00-M · LARR 25798

    Where to Use Pilkington Pyrostop

    • Fire-rated glass walls and full-height partitions
    • Fire-rated doors, sidelites and transoms
    • Corridors, stairs and other spaces where radiant heat transfer must be blocked
    • Exterior walls and storefronts (single glazed or IGU)
    • Schools, hospitals and public buildings needing heat-barrier, impact and optional bullet-resistant glazing
    • Pairs with fire-rated steel framing such as heat-barrier door/frame and curtain wall systems

    Good to Know

    Pilkington Pyrostop® is the heat-barrier (fire-resistive) option in this line-up; use it where your jurisdiction requires glazing tested to ASTM E119 / UL 263 or CAN/ULC-S101.

    Why Work With Precision Glass?

    From our Thornhill, Ontario facility, Precision Glass Services Inc. provides fire-resistant glass solutions that protect people and property, working with architects, contractors, glaziers and building owners. We help you match the right FireLite® or Pilkington Pyrostop® product to your opening, fire rating and code requirements.

    • Help selecting the right product for your fire rating, location and impact-safety needs
    • Guidance on compatible fire-rated frames and door assemblies
    • Technical data and product documentation on request
    • Local support from our Thornhill, Ontario office

    Call (905) 731-7800 · Fax (905) 709-4437 · 2 Essex Avenue, Unit 3B, Thornhill, Ontario L3T 3Y8

    Resources